Monomer high voltage alarm 3.500 V Monomer high pressure recovery 3.400 V Monomer low pressure alarm 2.900 V Monomer low pressure recovery 3.000 V Monomer overvoltage protection 3.650 V Monomer overvoltage recovery 3.400 V Monomer undervoltage protection 2.700 V Monomer undervoltage recovery 2.900 V Equalization opening voltage 3.350 V Battery low voltage forbidden charging 1.500 V Total pressure high pressure alarm 54.00 V Total pressure and high pressure recovery 50.50 V Total pressure low pressure alarm 43.50 V Total pressure and low pressure recovery 45.00 V Total_voltage overvoltage protection 54.75 V Total pressure overpressure recovery 50.50 V Total_voltage undervoltage protection 39.00 V Total pressure undervoltage recovery 45.00 V Harging overvoltage protection 63.00 V Charging overvoltage recovery 61.00 V Charging high temperature warning 50.0 Charging high temperature recovery 47.0 Charging low temperature warning 2.0 Charging low temperature recovery 5.0 Charging over temperature protection 55.0 Charging over temperature recovery 50.0 Charging under-temperature protection -10.0 Charging under temperature recovery 0.0 Discharge high temperature warning 52.0 Discharge high temperature recovery 47.0 Discharge low temperature warning -10.0 Discharge low temperature recovery 3.0 Discharge over temperature protection 55.0 Discharge over temperature recovery 50.0 Discharge under-temperature protection -15.0 Discharge under temperature recovery 0.0 Cell low temperature heating 0.0 Cell heating recovery 10.0 Ambient high temperature alarm 50.0 Ambient high temperature recovery 47.0 Ambient low temperature alarm 0.0 Ambient low temperature recovery 3.0 Environmental over-temperature protection 60.0 Environmental overtemperature recovery 55.0 Environmental under-temperature protection -10.0 Environmental undertemperature recovery 0.0 Power high temperature alarm 90.0 Power high temperature recovery 85.0 Power over temperature protection 100.0 Power over temperature recovery 85.0 Charging overcurrent warning 100.00 Charging overcurrent recovery 95.00 A Discharge overcurrent warning -205.00 A Discharge overcurrent recovery -203.00 A Charge overcurrent protection 210.00 A Discharge overcurrent protection -210.00 A Transient overcurrent protection -280.00 A Output soft start delay 2000 mS Battery rated capacity 200.00 Ah SOC 200.00 Ah Cell invalidation differential pressure 0.50 V Cell invalidation recovery 0.30 V Equalization opening pressure difference 0.030 V Equalization closing pressure difference 0.020 V Static equilibrium time 10 When Battery number in series 15 String Charge overcurrent delay 10 S Discharge overcurrent delay 10 S Transient overcurrent delay 30 mS Overcurrent delay recovery 60 S Overcurrent recovery times 5 times Charge current limit delay 5 Minutes Charge activation delay 1 Minutes Charging activation interval 10 When Charge activation times 10 times Work record interval 30 Minutes Standby recording interval 240 Minutes Standby shutdown delay 48 When Remaining capacity alarm 15 % Remaining capacity protection 8 % Interval charge capacity 96 % Cycle cumulative capacity 20 % Connection fault impedance 10.0 mO Compensation point 1 position 9 String Compensation point 1 impedance 0.0 mO Ompensation point 2 position 13 String Compensation point 2 impedance 0.0 mO